TA-DC-DD 60W Manual Operation
Model | TA-DC-60DD |
Output Power | 60KW |
Output Current | 0-200A |
Output Voltage | 200-750V (200-1000V optional) |
Frequency | L+N+PE |
Input Current | 95A |
Input voltage | AC380V士20% |
Gun quantity | ONE/TWO (CCS-1/CCS-2/CHAdeMO/GBT) |
Charging way | Quick or Slow charge automatic switch |
charging mode | SWIPEARD.APP.MANUAL |
Display | 5″Color Touch Screen |
Networkconnection | Standard configuration :CAN/485/ Ethernet Selective configuration:GPRS/4G |
Dimension(cm) | 72*45*160 |
Weight | 200KG |
OperatingTemperature | -20C to +50°C |
Altitude | 2000M |
IP LEVEL | IP54 |
Working Relative Humidity | RH≤95% |
Input cablelength | 0M(Customization Acceptable) |
Gun cableLength | 5M(Customization Acceptable) |
Interface Standard | CCS CHADEMO GB/T |
Charging protocol | GBT27930/CHADEMO 2.0/ DIN 701210CPP 1.6(JSON)ISO 15118 |
1.1 Pre operation inspection
Before running, please carefully check and ensure the following:
·The installation position of the charging station is convenient for operation and maintenance;
· Connect the charging station and accessories correctly and install them firmly;
· Reasonable selection and installation of AC incoming leakage protec- tion circuit breakers;
·The relevant accessories of the charging station are complete, and the charging gun is in a suspended state.
1.2 Power on the device
After all the pre operation inspection items meet the requirements, close the power supply incoming leakage protection circuit breaker. After powering
on, observe the status of the LED indicator light
·Normal standby: The blue light is always on
·Charging status: Green light always on
·Equipment malfunction: Red light always on
1.3 Technical indicators
1. AC input voltage: 380V±15%
2. Grid frequency:50Hz~60HZ
3. Output current level:5A~200A
4. Rated output voltage: 450V~1000V
5. Output voltage range: 200V~750VDC
6. Voltage accuracy: ≤±0.5%
7. Current accuracy: ≥30A:Not more than ±1%;<30A:Not more than ±0.3A
8. Voltage regulation accuracy:≤±0.5%
9. Steady flow accuracy:≤±1%
10. Ripple coefficient: RMS: no more than ±0.5%; peak value: no more
than ±1%
11. Current unbalance:≤5%
12. Standby power consumption: ≤0.1% output rated power
13. Total harmonic current: ≤5%
14. Efficiency: ≥93%
15. Full load power factor: ≥0.99
16. Load class: continuous operation at rated output current of class I
(100%)
17. Automatic current limiting feature: when the output current exceeds
the output current limiting set value, the constant current output will not
increase the output current
18. Output short-circuit protection: When the output is short-circuited,
the module will protect itself to prevent damage, and it can automatically
resume work after troubleshooting
19. Output overvoltage protection: the output voltage will automatically
stop output when the output voltage exceeds the rated output voltage 5%±5-
VDC to prevent damage to the equipment
20. Start delay: 5S-8S
21. Insulation resistance: ≥10M
22. Dielectric strength: output to ground, input to ground, input to output
2.5KVAC, no arcing and no flashover for 1min
23. Oscillating wave immunity: Class 3 (1MHz and 100kHz)
24. Electrostatic Discharge Immunity: Class 3